ADSS preformed tension set 200M span includes helical guy grip, protector rods, accessories like HDG U shackle, Galv.
Contact Now
ADSS preformed tension set , single-layer twisted wire can be used below 200 meters; high-tension strain clamp, double-layer twisted wire can be used for spans above 200 meters. The technical parameters required for the quotation are: the diameter of the applied wire, the range of use, the tensile force and so on.Composition: inner rods, helical guy grip, thimble clevis, U shackle, extension ring, etc.Product parameter According to different needs, the configuration intensity is 70kNSn Model No.
Contact Now
The structure of the preformed armor rod and the short protective rod is simple. A set of pre-twisted wires form an empty tube, which generates a gripping force when wrapping the wire, thereby protecting the wire. The pre-twisted wire protection line is used for vibration protection and has been included in the hardware products.
Contact Now
Medium and large tension set are composed of a double-layer twisted wire structure. The tension inner rods is made of galvanized steel wire or aluminum-clad steel wire, and the inner wall of the pre-stranded wire is stuck with a layer of fine emery to increase friction. The inner rods includes 4 groups, during processing in the factory to avoid installation errors and facilitate quick installation. The ends of the pre-twisted wires are bent radially outward to avoid squeezing and damaging the optical cable.
Contact Now
Applications 1.Tensile clamps for OPGW optical cables are mainly used to connect optical cables with a breaking strength of 160kN and below to tensile poles, corner poles and terminal poles. The complete set of OPGW optical cable strain clamp includes outer pre-twisted wires, inner pre-twisted wires, supporting connectors and grounding wires.
Contact Now
Galvanized steel thimble rope is compatible with tension set thickness 2.5mm and hot dip galvanized.
Contact Now
The structure of the preformed strain clamp is straightforward, and its pre-twisted cord legs are twisted to form an empty tube, and the rear part is a pre-formed twisted ring. the empty tube shaped via the legs of the pre-twisted twine can generate a robust grip while it's far wound at the wire, and the twisted loop is used to restore the insulator.
Contact Now
100M span ADSS cable tension set is used to connect to the pole and tower in the erection of wires and optical cables.
Contact Now
Preformed inner protection line rods:The material is aluminum-clad steel wire, which is the same material as all the aluminum-clad steel wires of OPPC cable. The inner wall of the protector rods is glued with a layer of gold steel sand through a high-strength polymer water-soluble environmentally friendly adhesive to increase the friction with the optical cable. The rods is preformed into four sub-bundles during production, which is convenient for quick installation.
Contact Now
Large span tension set for ADSS with advantages below:1.One-stop raw material supply completely2.Stable transmission, low loss3.Fast delivery, safe package, long service lifeSn Model No. Suitable for ADSS cable range(mm) 300M spanANZ 030/0940 8.6-9.4ANZ 030/1010 9.5-10.1ANZ 030/1070 10.2-10.7ANZ 030/1140 10.8-11.4ANZ 030/1220 11.5-12.2ANZ 030/1290 12.3-12.9ANZ 030/1370 13.0-13.7400M spanANZ 040/1220 11.5-12.2ANZ 040/1290 12.3-12.9ANZ 040/1370 13.0-13.7ANZ 040/1460 13.8-14.6ANZ 040/1550 14.7-15.5ANZ 040/1650 15.6-16
Contact Now
1.The short span ADSS tension set is used for the installation of ADSS cable, includes ADSS guy grip, Galvanized thimble clevis and U shackle. 2. The structure of the short span ADSS guy grip is simple. When installation, the tubular structure formed by the legs of the pre-twisted wire can be naturally wound on the ADSS cable to produce a strong grip. The novel structure and unique design make the wire resistant to tension.
Contact Now
Composition: inner stranded wire, outer stranded wire, embedded ring, PD type hanging plate, U type hanging ring, etc. Purpose: To withstand full tension. Connect the optical fiber composite ground wire to the terminal, tensile strength (rotation angle greater than 25°) or the optical cable connection pole. Features: a. The stress distribution is uniform and there is no stress concentration point, which can protect the optical cable well. b.
Contact Now
Tension set ADSS cables installation requires a special tangent assembly or a mechanical dead end at each pole. Tension clamp helical spiral usually with several numbers of rods, such as 7 of rods and thickness of each rod can be different based on different requirements. 2.5mm is the most often cable sizes. And always be compatible with fitting accessories.Sn Model No.
Contact Now
1. The preformed guy grip is used for the installation of ACSR conductors. The product is with much more reliability and economy compared with the bolt-type & hydraulic strain clamps. 2. The structure of the preformed guy grip is simple. When installation, the tubular structure formed by the legs of the pre-twisted wire can be naturally wound on the conductor to produce a strong grip. The novel structure and unique design make the wire resistant to tension.
Contact Now
1.The preformed guy grip is used for the installation of ACSR conductors. The product is with much more reliability and economy compared with the bolt-type & hydraulic strain clamps.2. The structure of the preformed guy grip is simple. When installation, the tubular structure formed by the legs of the pre-twisted wire can be naturally wound on the conductor to produce a strong grip. The novel structure and unique design make the wire resistant to tension.
Contact Now
Features: a. Even stress distribution, no stress concentration point, can well protect the optical cable. b. Under the premise of not exceeding the lateral compression strength of the optical cable, it has a greater grip on the optical cable and can withstand greater tension. c. The grip strength of the optical cable is not less than: 95% of the ultimate tensile strength (UTS) of the optical cable, which is fully suitable for the needs of optical cable erectionProduct composition diagramProduct technical specification sheet: Sn Model No.
Contact Now
The stay rod is called stay set as well, it is a component used to connect the stay wire to the ground anchor.The stay rod are made of Q235B steel, hot dip galvanized surface treatment which used for LV & MV stay rod assembly installation. Both bow type and tubular type we can supply, the tubular type stay rods MV & LV(M16×1830mm; M20×2440mm)exported to most of African countries. Features:1. Material: high strength carbon steel2. Application: for stay rod assembly3. Dimension: M20×2440mm4. Finish: hot dip galvanized
Contact Now
The middle span ADSS tension set clamp composed of HDG U shackle, galvanized thimble clevis, Chain extension, outer rods and protector rods & inner rods.
Contact Now
Wire tension clamp for steel core aluminum stranded wire1. The wire clip has good corrosion resistance; the material is exactly the same as the wire, ensuring that the wire clip has a strong ability to resist electrochemical corrosion. 2. The wire clamp adopts a spiral design, which improves the seismic resistance of the wire, uniform stress distribution, does not damage the wire, and prolongs the service life of the wire. Product technical specification sheet: Sn Model No.
Contact Now
Wire tension clamp NL-50/8 for steel core aluminum stranded wire made of galvanized steel wire or alloy clad steel wire. 1. The preformed guy grip is used for the installation of ACSR conductors. The product is with much more reliability and economy compared with the bolt-type & hydraulic strain clamps. 2. The structure of the preformed guy grip is simple. When installation, the tubular structure formed by the legs of the pre-twisted wire can be naturally wound on the conductor to produce a strong grip.
Contact Now
The preformed top tie are all designed in a spiral structure and consist of two aluminum-clad steel wires. The central part of the power distribution cable is formed in the factory, and its shape can be matched with various insulators and wires.
Contact Now
Light short span tension set for ADSS cable diameter 11.0-12.0mm, tension strength 4KN, and max span 120 meters.The tension dead end guy grip is made of galvanized steel wire or aluminum-clad steel wire, and the inner wall of the pre-twisted wire is stuck with a layer of fine emery to increase friction.1.The short span ADSS tension set is used for the installation of ADSS cable, includes ADSS guy grip, Galvanized thimble clevis and U shackle. 2. The structure of the short span ADSS guy grip is simple.
Contact Now
The preformed strain clamp is used to bear full tension on the bare conductors and overhead insulated conductors in the power transmission and distribution line, and connect the conductors to the strain tower, which can replace the conventional bolt-type strain clamp and compression type strain Clamps and wedge-shaped strain clamps.Structure composition and material description 1. Non-twisted ring: standard form, suitable for small diameter wires; Stranded ring: suitable for larger diameter wires 2. Color code: starting mark of installation 3. Label: Indicate the
Contact Now
The medium and high tension strain clamps are composed of a double-layer twisted wire structure. The tensile inner twisted wire is made of galvanized steel wire or aluminum-clad steel wire. The inner wall of the pre-twisted wire is stuck with a layer of fine emery to increase friction. The pre-twisted wire is preformed into four sub-bundles during processing to avoid installation errors and facilitate quick installation. The ends of the pre-twisted wires are bent radially outward to avoid squeezing and damaging the optical cable.
Contact Now