Guy Grip Dead End For Stay Wire

A. The guy grip clamp has high strength and can grip firmly. The grip strength of the clamp is not more than 95% CUTS (calculated breaking force of stranded wire).

B. The stress distribution of the guy grip clamp to the stranded wire is even, without damaging the stranded wire, which improves the anti-vibration ability of the stranded wire and greatly extends the service life of the wire.

C. Simple installation for easy construction. construction time be shorten a lot, without any special tools, one person can complete the operation.

D. The installation quality of the guy grip clamp is easy to guarantee, and the inspection can be carried out with sight without special training.

E. Good corrosion resistance, use high-quality materials. The material is exactly the same as the wire, ensuring that the wire clamp has strong resistance to chemical corrosion.


  Contact Now
Product Details

1. The twisting direction of the steel stranded wire and the matching preformed guy grip needs to be the same, and the tensile strength of the galvanized steel wire is 1370N/mm2-1470N/mm2. 

2. The white corundum used to increase the friction between the pre-twisted wire and the surface should meet the requirements of GB/T 2479.

3. The surface of the preformed guy grip should be smooth and free of defects such as cracks, folds and scars.

4. The size and tolerance of the pre-twisted wire The size of the pre-twisted wire should meet the requirements of the design drawings, or the technical conditions agreed by the buyer and the seller.

5. The total length, pitch and inner diameter of the preformed guy grip should be within the error range specified in the design drawing. The pitch is the arithmetic average of the measured 5 pitches.

6. The monofilament diameter error and ovality of the preformed guy grip shall meet the design requirements.

7. The spiral direction of the preformed guy grip should be consistent with the outer spiral direction of the wire or stranded wire.

 Product technical specification sheet:

Sn

 Model No.     

Suitable conductor range (mm)

Suitable conductor  (mm2)

1

NL-16/G

4.76

16

2

NL-25/G

6.6

25

3

NL-35/G

7.65-7.95

35

4

NL-50/G

8.95-9.3

50

5

NL-70/G

10.82-11.1

70

6

NL-95/G

12.5

95

7

NL-100/G

13.0

100

8

NL-120/G

14.0

120

9

NL-150/G

15.75

150

 

detail.jpg 

Using tips

1. Due to the special structure of the guy grip, only be used once after being stressed, and cannot be reused.

2. The specification and model of the guy grip must be provided when an inquiry.

3. It is not allowed to overlap on the guy grip, but it is allowed to overlap the conductors& cables.

4. The lay direction between the guy grip and the conductor & cables should be consistent. In general, we do right-hand direction mostly,  if you need left-handed guy grip, please be kindly inform in advance and we customize.

 