Preformed Guy Grips Dead For Stay Wire

The Dead end preformed guy grip for cable is used to fix the cable of various poles and towers. It can replace the UT cable clamp and wedge clamp that are commonly used to fix the cable at present. 

A. The guy grip clamp has high strength and can grip firmly. The grip strength of the clamp is not more than 95% CUTS (calculated breaking force of stranded wire).

B. The stress distribution of the guy grip clamp to the stranded wire is even, without damaging the stranded wire, which improves the anti-vibration ability of the stranded wire and greatly extends the service life of the wire.

C. Simple installation for easy construction. construction time be shorten a lot, without any special tools, one person can complete the operation.

D. The installation quality of the guy grip clamp is easy to guarantee, and the inspection can be carried out with sight without special training.

E. Good corrosion resistance, use high-quality materials. The material is exactly the same as the wire, ensuring that the wire clamp has strong resistance to chemical corrosion.


  Contact Now
Product Details

The preformed dead end is used to fix the cable clamp of the cable of the tower, the iron tower, and the microwave tower. It can replace the U-T clamp and the wedge clamp that are commonly used to fix the cable on the line tower.

 

The unique design makes the tension-resistant structure of the cable simple and reliable. After installation, the empty tube formed by the twisting of the two legs of the pre-twisted wire of the wire clip can be wound on the cable to produce a strong grip. The twisted ring is used to fix the ground anchor. Or on the tower pole. The material is usually galvanized steel wire.

Product technical specification sheet:

Sn

 Model No.     

Suitable conductor range (mm)

Suitable conductor  (mm2)

1

NL-16/G

4.76

16

2

NL-25/G

6.6

25

3

NL-35/G

7.65-7.95

35

4

NL-50/G

8.95-9.3

50

5

NL-70/G

10.82-11.1

70

6

NL-95/G

12.5

95

7

NL-100/G

13.0

100

8

NL-120/G

14.0

120

9

NL-150/G

15.75

150

 1634628462424438.jpg

Using tips

1. Due to the special structure of the guy grip, only be used once after being stressed, and cannot be reused.

2. The specification and model of the guy grip must be provided when an inquiry.

3. It is not allowed to overlap on the guy grip, but it is allowed to overlap the conductors& cables.

4. The lay direction between the guy grip and the conductor & cables should be consistent. In general, we do right-hand direction mostly,  if you need left-handed guy grip, please be kindly inform in advance and we customize.

 


Product form