Preformed Helical Guy Grip Clamp

Preformed helical guy grip clamp is suitable for overhead line ADSS optical cable, usage of poles and towers. For the integrity and performance of the ADSS tension set clamp function, in principle, the preformed dead end clamp can only be used once to keep safety and it is not allowed to repeat using. For good performance and personal safety, it is necessary to make sure whether the model and specifications of the fittings are consistent with the requirements of the optical cable before use.

  Contact Now
Product Details

Preformed helical guy grip clamp with long span helical dead end, thimble clevis, U shackle, link fitting and pole attachment with related accessories. The spiral rods has sandy cover, excellent tensile properties, good resistance to oxidation and corrosive agents.

Preformed Guy Wire Grip ADSS Helical,Cable Clamp Dead End Helical Preformed,Helical Tension Clamp for ADSS

Sn Model No. Suitable for ADSS cable range(mm) 
300M spanANZ 030/0940 8.6-9.4
ANZ 030/1010 9.5-10.1
ANZ 030/1070 10.2-10.7
ANZ 030/1140 10.8-11.4
ANZ 030/1220 11.5-12.2
ANZ 030/1290 12.3-12.9
ANZ 030/1370 13.0-13.7
400M spanANZ 040/1220 11.5-12.2
ANZ 040/1290 12.3-12.9
ANZ 040/1370 13.0-13.7
ANZ 040/1460 13.8-14.6
ANZ 040/1550 14.7-15.5
ANZ 040/1650 15.6-16.5
500M span ANZ 050/1370 13.0-13.7
ANZ 050/1460 13.8-14.6
ANZ 050/1550 14.7-15.5
ANZ 050/1650 15.6-16.5


Installation steps: 

  1. Align the installation mark of the outer wire with the optical cable and mark the installation.

图片1.png

2.Align the first set of inner wire marks with the optical cable marks. 

图片2.png

3.The third group does the same as the second group. 

图片3.png

4.All the inner wires are installed. 

图片4.png

5.Align the outer wire installation mark with the inner wire installation mark.

图片5.png

6.Wrap one leg first. 

图片6.png

7.Wind the other leg again.

图片7.png

8. Wrap the end of the outer wire well.

图片8.png


Product form