Suspension String For OPGW Cable

Suspension set clamp ADSS are mainly used for the suspension and support of optical cables on straight poles. It bears the weight (ice, snow) of the optical cable, and disperses the radial compressive stress, so as to protect the optical cable and avoid abnormal conditions such as excessively small bending radius and stress concentration of the optical cable.


  Contact Now
Product Details

Material 

1. Rubber Clamps

Composed of high-quality rubber and center reinforcement, it has the properties of ozone resistance, chemical resistance, weather resistance, high and low temperature performance, high strength and elasticity, and small compression deformation.

2. Aluminum splint

It is made of corrosion-resistant aluminum alloy by pressure casting. The aluminum alloy has stable chemical properties, good atmospheric corrosion resistance and good mechanical properties. (Official account: transmission and distribution lines)

3. Protection line armor rod 

The aluminum alloy wire is customized according to the predetermined mechanical properties and chemical composition. It has high tensile strength, hardness, good elasticity and strong anti-rust ability, and can be used for a long time in harsh weather conditions.

4. Outer armor wire

Same as pre-twisted wire with guard line.   

5. Ground earth wire

   

Product composition diagram: 

composition.png

Product technical specification sheet:

 

Sn

Model No.

Suitable cable range(mm)

Inner rod

Outer rods

1

OCL 0800

7.4-8.0

Aluminum alloy wire Φ3.7

Aluminum alloy wire Φ5.18

2

OCL 0880

8.1-8.8

3

OCL 0960

8.9-9.6

4

OCL 1010

9.7-10.1

5

OCL 1060

10.2-10.6

6

OCL 1110

10.7-11.1

7

OCL 1160

11.2-11.6

8

OCL 1170

11.7

Aluminum alloy wire Φ4.3

Aluminum alloy wire Φ6.3

9

OCL 1200

11.8-12.0

10

OCL 1270

12.1-12.7

11

OCL 1290

12.8-12.9

12

OCL 1360

13.0-13.6

13

OCL 1410

13.7-14.1

14

OCL 1430

14.2-14.3

15

OCL 1450

14.4-14.5

16

OCL 1510

14.6-15.1

17

OCL 1580

15.2-15.8

18

OCL 1600

15.9-16.0

19

OCL 1690

16.1-16.9

20

OCL 1730

17.0-17.3

21

OCL 1800

17.4-18.0

22

OCL 1840

18.1-18.4

 

 

Safety Note 

It must be ensured that the extreme contact pressure under the fitting does not exceed the extrusion design limit of the ADSS optical cable. In the use of the tension value, it is necessary to ensure that the ADSS optical cable and the wire do not whip, and the load on the tower is as small as possible to avoid safety problems.

 






Product form