Formed Wire Dead End for ADSS Cable

Dead end guy grip component is suitable for overhead line ADSS optical cable, usage of poles and towers. For the integrity and performance of the ADSS tension set clamp function, in principle, the preformed dead end clamp can only be used once to keep safety and it is not allowed to repeat using. For good performance and personal safety, it is necessary to make sure whether the model and specifications of the fittings are consistent with the requirements of the optical cable before use.

  Contact Now
Product Details

Composition: inner stranded wire, outer stranded wire, embedded ring, PD type hanging plate, U type hanging ring. 

Purpose: To withstand full tension. 

Features: 

a.The outer stranded wire is directly connected to the pole tower through the connecting fittings such as the embedded ring, and bears the line load. 

b. The inner twisted wire protects the ADSS optical cable.

Technical specification: 

-Design for quick and easy installation

-Minimizing time consuming civil works 

-Provide a future proof aerial network

-Temperature: -10°C up to +70°C

Formed Wire Dead End for ADSS Cable

Sn

Model No.

Suitable for ADSS cable range(mm)

300M span

ANZ 030/0940

8.6-9.4


ANZ 030/1010

9.5-10.1


ANZ 030/1070

10.2-10.7


ANZ 030/1140

10.8-11.4


ANZ 030/1220

11.5-12.2


ANZ 030/1290

12.3-12.9


ANZ 030/1370

13.0-13.7

400M span

ANZ 040/1220

11.5-12.2


ANZ 040/1290

12.3-12.9


ANZ 040/1370

13.0-13.7


ANZ 040/1460

13.8-14.6


ANZ 040/1550

14.7-15.5


ANZ 040/1650

15.6-16.5

500M span

ANZ 050/1370

13.0-13.7


ANZ 050/1460

13.8-14.6


ANZ 050/1550

14.7-15.5


ANZ 050/1650

15.6-16.5

Installation steps: 

1.Align the installation mark of the outer wire with the optical cable and mark the installation. 

ADSS terminating helix dead end

2.Align the first set of inner wire marks with the optical cable marks. 

ADSS terminating helix dead end

3.The third group does the same as the second group. 

ADSS terminating helix dead end

4.All the inner wires are installed. 

ADSS terminating helix dead end

5.Align the outer wire installation mark with the inner wire installation mark.

ADSS terminating helix dead end

6.Wrap one leg first. 

ADSS terminating helix dead end

7.Wind the other leg again.

ADSS terminating helix dead end

8. Wrap the end of the outer wire well.

ADSS terminating helix dead end


Product form