A. The guy grip clamp has high strength and can grip firmly. The grip strength of the clamp is not more than 95% CUTS (calculated breaking force of stranded wire).
B. The stress distribution of the guy grip clamp to the stranded wire is even, without damaging the stranded wire, which improves the anti-vibration ability of the stranded wire and greatly extends the service life of the wire.
C. Simple installation for easy construction. construction time be shorten a lot, without any special tools, one person can complete the operation.
D. The installation quality of the guy grip clamp is easy to guarantee, and the inspection can be carried out with sight without special training.
E. Good corrosion resistance, use high-quality materials. The material is exactly the same as the wire, ensuring that the wire clamp has strong resistance to chemical corrosion.
Wire tension hardware for steel core aluminum stranded wire
1. Large grip strength of the clamp and high safety performance. It is used for transmission and distribution lines such as steel stranded wire, aluminum stranded wire, steel core aluminum stranded wire, insulated wire, etc. The pre-stranded strain clamp grip can reach 100% of the stranded wire calculation breaking force or above.
2. The pre-twisted clamp is simple to install and easy to construct. It does not require any special tools. One person can complete the operation. The installation quality is easy to guarantee, and the consistency is strong. It can be inspected on site with the naked eye.
Product technical specification sheet:
Sn | Model No. | Suitable for conductor range(mm) | Conductor type | |
Min | Max | |||
1 | NL-35/6 | 7.35 | 8.26 | 35/6 |
2 | NL-50/8 | 9.26 | 10.39 | 50/8 |
3 | NL-70/10 | 10.4 | 11.68 | 70/10 |
NL-50/30 | 50/30 | |||
4 | NL-70/40 | 13.12 | 14.66 | 70/40 |
NL-95/15 | 95/15 | |||
NL-95/20 | 95/20 | |||
NL-120/7 | 120/7 | |||
5 | NL-120/20 | 14.67 | 16.59 | 120/20 |
NL-95/55 | 95/55 | |||
NL-120/25 | 120/25 | |||
NL-185/8 | 185/8 | |||
6 | NL-150/20 | 16.6 | 18.77 | 150/20 |
NL-120/70 | 120/7 | |||
NL-150/25 | 150/25 | |||
NL-150/35 | 150/35 | |||
NL-185/10 | 185/10 | |||
7 | NL-185/25 | 18.78 | 21.26 | 185/25 |
NL-185/30 | 185/30 | |||
NL-210/10 | 210/10 | |||
NL-185/45 | 185/45 | |||
NL-210/25 | 210/25 | |||
NL-210/35 | 210/35 | |||
NL-210/50 | 210/50 | |||
8 | NL-240/30 | 21.27 | 24.05 | 240/30 |
NL-240/40 | 240/40 | |||
NL-240/55 | 240/55 | |||
NL-300/15 | 300/15 | |||
NL-300/20 | 300/20 | |||
NL-300/25 | 300/25 | |||
NL-300/40 | 300/40 | |||
9 | NL-300/50 | 24.06 | 27.2 | 300/50 |
NL-300/70 | 300/70 | |||
NL-400/20 | 400/20 | |||
NL-400/25 | 400/25 | |||
NL-400/35 | 400/35 | |||
10 | NL-400/50 | 27.21 | 30.78 | 400/50 |
NL-400/65 | 400/65 | |||
NL-400/95 | 400/95 | |||
NL-500/35 | 500/35 | |||
NL-500/45 | 500/45 | |||
NL-500/65 | 500/65 |
Using tips
1. Due to the special structure of the guy grip, only be used once after being stressed, and cannot be reused.
2. The specification and model of the guy grip must be provided when an inquiry.
3. It is not allowed to overlap on the guy grip, but it is allowed to overlap the conductors& cables.
4. The lay direction between the guy grip and the conductor & cables should be consistent. In general, we do right-hand direction mostly, if you need left-handed guy grip, please be kindly inform in advance and we customize.
Submitted successfully
We will contact you as soon as possible